Auto Correction &

Averaging x last fillings

When ‘Auto Correction’ is checked, the board tries to correct the filling amount, based on the results of the last x fillings.

E.4.1.2 Auto Tare

Activate

When not checked, the Setpoint defines the requested final gross weight.

That is, if the setpoint is 100 kg and the starting gross weight is 90 kg, the filling amount will be 10 kg.

The next two parameters (Hi/Lo Limits) are irrelevant.

When checked, the Setpoint defines the requested filling amount.

That is, if the setpoint is 100 kg, the filling amount will also be 100 kg, regardless of the starting gross weight. However, the filling operation will take place only if the starting gross weight, as found in accordance with the Stabilization Criterion (section E.4.1.4), is within the range defined by the following two parameters (Hi/Lo Limits). Otherwise, the filling operation will be rejected and an error will be reported.

Hi Limit

When ‘Auto Tare’ is activated, specifies the high allowed tare limit.

Lo Limit

When ‘Auto Tare’ is activated, specifies the low allowed tare limit.