E.4.2 Filling By = Time

E.4.2.1 Filling by Time Parameters

Setpoint #x

The required total filling time when the user selects setpoint #x (x = 1, 2 or 3).

Slow Amount

The required slow filling time, in % of the current Setpoint (a tip shows the value of Slow Amount in ms).

Specify ‘0’ when only one speed is required.

E.4.2.2 Stabilization Criterion (Stop)

At the end of a filling cycle the board waits for the scale to stabilize before proceeding to the next cycle. The size of this waiting delay is specified by the ‘‘Delta Time’’ parameter.

Delta Time

See the description above.

E.4.3 Fast Speed Config

Option1

Fast Speed = Output #1

Slow Speed = Output #2

Option2

Fast Speed = Output #1 + Output #2

Slow Speed = Output #2

74