E.6 Commands

Enter & Exit Fill Mode

F Enter Fill Mode (from General Mode)

xExit Fill Mode (to General Mode) (small ‘x’) Inside the Fill Mode

gStart filling (‘g’ stands for ‘go’) (like input #2 does).

t Terminate an error status (like input #3 does).

e Emergency stop (like input #4 does).

r Get filling(s) report Response Example:

# 1 A= 40.99 Tr= 6.65 Cv= 0.00 Ft= 7527 ms St= 2554 ms Cc= 0

Legend: Filling #1, Actual (=final) weight=40.99, Tare=6.65, Correction Value=0.00,

Fast time=7527 ms, Slow time=2554 ms,

Completion Code=0 (0 is normal, otherwise it’s an error code). Notes:

1.The actual (final) weight (40.99 in the example) is:

*net weight if Auto Tare is selected

*gross weight if Auto Tare is not selected.

2.The reports are accumulated in a FIFO whose size is 30 fillings. That is, only up to last 30 reports are available. Note: The FIFO size (30) is subject to change in the various versions.

3.Please refer also to section 3.3.2.1.4.

FGet fillings summary: Number of normal fillings.

Number of each error type cases for each error type that occurred at least once.

77

Page 78
Image 78
Omega Speaker Systems LCIC-WIM-BEN manual # 1 A= 40.99 Tr= 6.65 Cv= 0.00 Ft= 7527 ms St= 2554 ms Cc=