| c. Get a single reading of: |
|
|
| weight, A/D or temperature: |
. |
| Get weight (after Filter2, not rounded to resolution). | |
? |
| Get weight (after Filter2, rounded to resolution). | |
> |
| Get A/D reading after Filter1. | |
< |
| Get A/D reading after Filter2. | |
| T |
| Get temperature |
| d. Analog output: Read & write voltage: | ||
@ |
| Gets the analog output voltage (in Volts). | |
| vx<c/r> |
| Sets the analog output voltage to x Volts. |
|
| The analog output voltage is measured at pin 12 of CONN6 | |
| (lower case v) |
| |
|
| with respect to pin 13 which is ground. | |
|
|
| |
|
| e. Digital Outputs: Write outputs: | |
| a |
| Turn on Output1 if Manual |
| A |
| Turn off Output1 if Manual |
| b |
| Turn on Output2 if Manual |
| B |
| Turn off Output2 if Manual |
| c |
| Turn on Output3 if Manual |
| C |
| Turn off Output3 if Manual |
| d |
| Turn on Output4 if Manual |
| D |
| Turn off Output4 if Manual |
|
| f. Digital Outputs: Read outputs: | |
| O |
| Card returns a string of the form ‘xxxx<c/r>’, where x is |
|
| either “1” or “0” representing the status of the 4 output | |
| (upper case o) |
| |
|
| opto relays OUT4,OUT3,OUT2,OUT1 respectively. | |
|
|
| |
| g. Digital Inputs: Read inputs & toggling counter: | ||
| I |
| Card returns a string of the form 'xxxx<c/r>’, where x is |
|
| either “1” or “0” representing the digital input status of | |
| (upper case i) |
| |
|
| IN4,IN3,IN2,IN1 respectively. | |
|
|
| |
| i |
| Gets a 16 bit ‘toggling counter’. The ‘toggling counter’ |
|
| increments each time when input #2 is toggled. | |
|
|
|
30