Paradyne GranDSLAM 4200 4202 E1 Uplink Module Connectors, 120Ω Connector, 75Ω TX/RX Connectors

Models: GranDSLAM 4200

1 68
Download 68 pages 25.78 Kb
Page 56
Image 56

A. Connectors and Pin Assignments

4202 E1 Uplink Module Connectors

he 4202 E1 Uplink Module has two types of connectors, only one of which may be used at a time:

T120Connector

75Connector TX/RX Connectors

120Connector

The 120connector is a single, RJ48C, unkeyed, shielded, 8-pin modular jack. The shield is connected to ground via the module. Pin assignments for the 120connector are shown in Table A-7.

Table A-7. 4202 E1 Uplink Module 120Connector

Signal

Direction

Pin

 

 

 

Receive Ring

In

1

 

 

 

Receive Tip

In

2

 

 

 

NC

3

 

 

 

Transmit Ring

Out

4

 

 

 

Transmit Tip

Out

5

 

 

 

NC

In

6

 

 

 

NC

7

 

 

 

NC

8

 

 

 

75TX/RX Connectors

The 75TX/RX connectors each use coaxial cables that are unbalanced with respect to ground. The shield of the TX cable is connected directly to ground at the E1 module. The shield of the RX cable is capacitor-coupled to ground at the module. Pin assignments for the 75TX/RX connectors are shown in Table A-8.

Table A-8. 4202 E1 Uplink Module 75TX/RX Connectors

Signal

Direction

Pin

 

 

 

Transmit

Out

Coax Center Conductor

 

 

 

Transmit Signal and Chassis Ground

Barrel

 

 

 

Receive

In

Coax Center Conductor

 

 

 

Receive return path (not grounded)

Out

Barrel

 

 

 

A-6

October 2002

4200-A2-GN20-10

Page 56
Image 56
Paradyne GranDSLAM 4200 manual 4202 E1 Uplink Module Connectors, 120Ω Connector, 75Ω TX/RX Connectors