1. Installation

Cables Required

Table 1-2shows all the cables that may be required for your installation.

Table 1-2. Cable Descriptions

Connector Name

Connector and Cable

For Connecting . . .

 

 

 

DSL PORTS 1–24

50-pin RJ21X Telco-type

Up to 24 DSL ports to Main

 

straight connector and 50-wire

Distribution Frame, punchdown

 

cable. Two cables required, one

block, or splitters.

POTS 1–24

for DSL and one for POTS (if

Up to 24 POTS splitter ports to

used).

 

Main Distribution Frame or

 

 

 

 

punchdown block.

 

 

 

4201 T1 MODULE:

 

A downstream

100

RJ48C

GranDSLAM 4200 to an

upstream ATM network.

 

 

 

 

 

4202 E1 MODULE:

 

A downstream

TTX/RX 75

TBNC

upstreamGranDSLAMATM4200network.to an

120

RJ48C

 

 

 

 

4203 T1/E1 IMA

RJ48C

A downstream

MODULE

 

GranDSLAM 4200 to an

 

 

Tupstream ATM network.

 

 

A GranDSLAM 4200

 

 

aggregation unit to a basic

 

 

unit in a stack.

 

 

 

MGMT

8-position modular plug and

he GranDSLAM 4200 to a

 

8-wire Category 5 or better

Network Management System

 

unshielded twisted pair (UTP)

over a Local Area Network (LAN)

 

cable.

employing 10BaseT or

 

 

100BaseT.

 

 

 

CONSOLE

DB9 plug connector and

he GranDSLAM 4200 to one of

 

shielded cable.

the following:

 

The other connector

A terminal or a PC with a

 

depends on the serial port on

terminal emulation program,

 

your terminal or PC, but

Tor

 

Tnormally is a DB9 socket.

 

 

The other connector

A modem.

 

depends on the serial port on

 

 

your modem, but normally is

 

 

a DB25 plug.

 

 

 

 

4210 ALARM

3-position terminal block and

The GranDSLAM 4200 to an

 

3-wire shielded, twisted-pair

alarm system.

 

cable.

 

 

 

 

4220/4230 ALARM

5-position terminal block and

The GranDSLAM 4200 to an

 

5-wire shielded, twisted pair

alarm system.

 

cable.

 

 

 

 

BITS (Building

Not applicable.

For future use.

Integrated Timing

 

 

Supply)

 

 

 

 

 

4200-A2-GN20-10

October 2002

1-3

Page 13