2. Cabling

Procedure

To connect the ALARM interface:

1.Strip the tips of the alarm source wires (about 1/2 inch or 12.7 mm in length).

2.For Model 4210, insert the wires into the 3-position plug. Securely fasten each wire by tightening the screw above it.

For Models 4220/4230, use a screwdriver to press the orange spring tab in while inserting the wire into the hole below it.

NOTE:

For all models, the insulation should be fully within the plug and no bare wire should be exposed outside of the plug.

Spring

Tab

02-17283

02-17328

 

3.Insert the plug into the ALARM interface on the front panel of the GranDSLAM 4200.

4.If the GranDSLAM 4200 is in a rack, dress the cable to the left and secure it to the rail with a cable tie.