OnSite Series Getting Started Guide

3 • Installation Overview

 

 

Note Take care to load the rack so that it is not top heavy.

Note Do not cover vents that would restrict airflow. Leave a minimum of a half-rack space above and below the OS-10 system for adequate ven- tilation.

3.Secure the chassis using four 12-24 x 3/4-inch screws (two screws for each side) through the elongated holes in the L bracket nearest to the chassis and to the threaded holes in the mounting post. Use a suitable screwdriver for this task.

4.Tighten any loose captive installation screws on the expansion slot front panel covers.

Figure 10. Mounting the OS-10 System Chassis in an EIA/TIA 19-Inch Rack

Mounting the Chassis to an ETSI Rack

To install the OS-10 system chassis in an ETSI 300-mm rack, see Figure 11 and follow these steps:

1.Install the two L mounting brackets in the orientation shown in Figure 11. Insert and fully tighten the screws to secure the brackets to the chassis (four screws for each bracket). Use a suitable screwdriver for this task.

Note For this rack configuration, the L mounting bracket holes are posi- tioned 50 mm back from the front panel of the OS-10 system, as shown in Figure 11.

2.Position the chassis in the rack and align the mounting holes in the L bracket with the mounting holes in the equipment rack.

Note The mounting-hole pitch for the ETSI 300 mm rack is 25 mm.

Note Take care to load the rack so that it is not top heavy.

OnSite System Installation

30

Page 30
Image 30
Patton electronic 07MOS10xx-GS, 1063 manual Mounting the Chassis to an Etsi Rack