Checking the OS-10 System Installation

OnSite Series Getting Started Guide

3 • Installation Overview

 

 

9.Connect the negative lead of the circuit to the “B” power input lead on the OS-10 system terminal block. See wiring 3-B on figure 13 on page 36.

Note The terminal block indicates the “B” power lead by the letter B. This lead is third from the top on the OS-10 system terminal block.

Do not over torque the terminal block captive thumbscrew or ter- minal block contact screws.

CAUTION

10.Secure the wires using cable ties or similar appropriate cable tie-downs.

11.Turn on power to the DC circuit.

Note The green PWR (power) LED on the front panel is lit when the sys- tem receives power from the DC source.

Checking the OS-10 System Installation

When you first apply power to the system, the STAT (status) LED shows a solid amber light. This light indi- cates that the system is booting. The STAT LED turns to a solid green light when the system completes the boot process and is ready for operation.

OnSite System Installation

38