Installation and commissioning

8.08

Mounting/connectingthestartinhibitor (only on machines with Quick-flange motor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

92-015

2

3

4

Fig. 8 - 09

6

5

92-013

●For machines delivered without a table, the plate1 from the accessories should be mounted under the table top, so that the switch lug2 is resting on plate1 when the sewing head is in an upright position.

●Loosen screws3 and adjust switch 4 so that the switch lug2 is free when the sewing head is tilted back and pressed when the sewing head is upright.

●Connect plugs 5 and6 to the switch4.

Function check of the start inhibitor

ERROR

E 9

●Switch the machine on at the main switch and tilt it back. The error message "E9" must appear on the control panel.

●If the message does not appear, check the setting of switch 4.

●Set the sewing head upright and acknowledge the error message by pressing the TE/ Speed key. The machine is ready for operation again.

8 - 8