Installation and commissioning

8.08

Mounting/connectingthestartinhibitor (only on machines with Quick-flange motor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

92-015

2

3

4

Fig. 8 - 09

6

5

92-013

For machines delivered without a table, the plate1 from the accessories should be mounted under the table top, so that the switch lug2 is resting on plate1 when the sewing head is in an upright position.

Loosen screws3 and adjust switch 4 so that the switch lug2 is free when the sewing head is tilted back and pressed when the sewing head is upright.

Connect plugs 5 and6 to the switch4.

Function check of the start inhibitor

ERROR

E 9

Switch the machine on at the main switch and tilt it back. The error message "E9" must appear on the control panel.

If the message does not appear, check the setting of switch 4.

Set the sewing head upright and acknowledge the error message by pressing the TE/ Speed key. The machine is ready for operation again.

8 - 8