Installation and commissioning
8.08 | Mounting/connectingthestartinhibitor (only on machines with | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1
2
3
4
Fig. 8 - 09
6
5
●For machines delivered without a table, the plate1 from the accessories should be mounted under the table top, so that the switch lug2 is resting on plate1 when the sewing head is in an upright position.
●Loosen screws3 and adjust switch 4 so that the switch lug2 is free when the sewing head is tilted back and pressed when the sewing head is upright.
●Connect plugs 5 and6 to the switch4.
Function check of the start inhibitor
ERROR
E 9
●Switch the machine on at the main switch and tilt it back. The error message "E9" must appear on the control panel.
●If the message does not appear, check the setting of switch 4.
●Set the sewing head upright and acknowledge the error message by pressing the TE/ Speed key. The machine is ready for operation again.
8 - 8