Setting up

9 Settingup

All instructions and regulations in this instruction manual must be observed.

Special attention must be given to all safety regulations!

All setting-up work must only be done by personnel with the necessary training. For all setting-up work the machine must be isolated from its power supply by turning off the on/off switch or removing the machine plug from the electric power socket!

9.01 Insertingtheneedle

1

2

Switch off the machine! Danger of injury if the machine is started accidentally!

Only use needles of system 438.

Bring the needle bar into its highest position.

Loosen screw1.

Insert the needle2 as far as possible.

The long needle groove must be facing forwards.

Tighten screw1.

Fig. 9 - 01

9 - 1