Setting up

9 Settingup

All instructions and regulations in this instruction manual must be observed.

Special attention must be given to all safety regulations!

All setting-up work must only be done by personnel with the necessary training. For all setting-up work the machine must be isolated from its power supply by turning off the on/off switch or removing the machine plug from the electric power socket!

9.01 Insertingtheneedle

1

2

Switch off the machine! Danger of injury if the machine is started accidentally!

Only use needles of system 438.

●Bring the needle bar into its highest position.

●Loosen screw1.

●Insert the needle2 as far as possible.

●The long needle groove must be facing forwards.

●Tighten screw1.

Fig. 9 - 01

9 - 1