Care and maintenance

11.04

Cleaning the air filter of the air-filter / lubricator

 

 

8

 

6

 

10

 

 

 

100

 

4

 

150

12

 

 

50

 

200

 

 

 

14

2

 

230

0

 

 

 

 

16

0

2

1

Fig. 11 - 06

11.05 Checking/adjusting the air pressure

2

 

 

8

 

6

 

10

 

 

 

100

 

4

 

150

12

 

 

50

 

200

 

 

 

14

2

 

230

0

 

 

 

 

16

0

1

Switch the machine off! Disconnect the air hose at the air-filter / lubricator.

Todrainwaterbowl1:

Water bowl1 drains itself automatically when the compressed-air hose is disconnected from the air-filter / lubricator.

Cleaningfilter2:

Unscrew water bowl1.

Take out filter2.

Clean filter2 with compressed air or isopropyl alkohol ( part No. 95-665 735-91 ).

Screw in filter2 and screw on water bowl1.

Before operating the machine, always check the air pressure on gauge1.

Gauge 1 must show a pressure of6bar.

If necessary adjust to this reading.

To do so, pull knob 2 upwards and turn it so that the gauge shows a pressure of

6bar.

Fig. 11 - 07