Adjustment

12.07.05 Needle thread tension release

Requirement

1.When solenoids3 are activated, the tensions disks4 should be at least0.5mm apart.

2.When the thread trimmer is in its neutral position and the sewing foot is positioned on the needle plate, the tension should be fully effective.

2 1

92-047

3

0.5 mm

4

Fig. 12 - 41

57-05

92-013

Unscrew the thread wiper.

Turn nut 1 (nut2) in accordance with the requirements.

Screw thread wiper back into place.

12 - 42