Adjustment

12.09 Reset / Cold start

After selecting the reset menu, by pressing the corresponding key it is possible to delete seam parameters, delete seam programs and to carry out a cold start.

AD

Press and hold "+" on keysA andD and switch on the machine, seeChapter7.01Main switch.

1_ 2 _ _ _ 3 _

A BD

AResetting the seam parameters

● Press "+"onkey "A".

All parameters are deleted, the display "—rE—" appears for a short time on the screen.

BResetting the seam programs

● Press "+"onkey "B".

All seam programs are deleted, the display "—rE—nA" appears for a short time on the screen.

DCold start

● Press "+" onkey "D".

With the exception of the value for the machine class, the values of the machine control unit are set back to their basic values, the display "—COLd—" appears for a short time on the screen.

After the cold start all programmed values are set back to their status at the time of delivery. For this reason after a cold start it is necessary to re-enter first the parameter "800" and then the parameters "700" to "799".

12 - 46