Adjustment

12.05.25 Needle thread tension release (on machines without -900/24)

Requirement

When the hand lever is raised, the tensions disks should be at least0.5mm apart.

1

2

Fig. 12 - 26

4

3

0.5 mm

3

● Loosen screw1 and press linkage rod 2 down as far as possible. ● Raise the presser foot.

Adjust trip3 (screw4) in accordance with therequirement.

12 - 27