11.Remove the two screws that secure the lamp duct filter unit to the fuser, then remove the lamp duct filter unit and the foam gasket.

1

2

3

4

5

Legend:

1)Foam Gasket

2)Screw (4)

3)Filter Holding Plate

4)Lamp Filter (Air Filter)

5)Lamp Duct Filter Unit

12.Remove the two screws that secure the filter holding plate to the lamp duct filter unit, then remove the lamp filter.

13.Vacuum the lamp filter, then reinstall it.

14.Vacuum any paper dust from the printer frame.

15.Aligning the guide pins in the screw bracket with the holes in the side frame of the printer, install the fuser.