3–46 Configuring the PrinterOption ParameterValue Comments
Host Form Length DISABLE
ENABLE*
DISABLE
sets the form length to the value set from the front
panel.
ENABLE sets the printer page size equal to the
form
length defined in the CREATE FORM mode.
IGP 100 Compatibility DISABLE*
ENABLE DISABLE does not change the PGL behavior. ENABLE
makes PGL behavior compatible to that of IGP 100.
Power On IGP/PGL DISABLE
ENABLE*
DISABLE puts printer in QUIET mode at power-up,
otherwise
ENABLE or LISTEN mode is active at power-up.
Select SFCC 1 – 255 decimal
126 *
Select
any ASCII character on page in
Appendix D
(0 – 127)
to set the binary pattern for the selected Special Function
Control Character. Default is decimal 126 (~).
Uppercase DISABLE*
ENABLE
If ENABLED, all incoming data is converted to uppercase.
Select Font 0 *
1
2
3
4
5
6
7
8
9
10
0 = US ASCII 11–23 = Undefined default to ASCII.
1 = German 24–31 = User-defined symbol set
2 = Swedish from the USET command.
3 = Danish
4 = Norwegian
5 = Finnish
6 = English
7 = Dutch
8 = French
9 = Spanish
10 = Italian
Select LPI
1 – 10
Any integer value from 1 to 10. Default is 6.
Skip Cmd Prefix DISABLE
SKIP ALL
SPACES
ENABLE*
DISABLE prints text before a valid IGP/PGL command as
if a line feed preceded the command’s SFCC. SKIP ALL
SPACES ignores all spaces between the CR/LF and the
first
character of this
next command. ENABLE ignores any
text before a valid command.
Upc Descenders DISABLE
ENABLE*
If ENABLED, human readable text for UPC and EAN bar
codes
is embedded within the bar code. If DISABLED, the
text is printed below the bar code.
Slash øDISABLE*
ENABLE If DISABLED, prints zeros without a diagonal slash. If
ENABLED, prints zeros with a diagonal slash.