Psion Teklogix 8100107B user manual Discrete 2, Standard 2 of 5 Format

Models: 8100107B

1 396
Download 396 pages 8.07 Kb
Page 228
Image 228

Chapter 6: Settings

Decoded (Intermec ISCP)

Minimum Length

Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Field Size/Char

Refer to page 148 for details.

6.25.3.16 Discrete 2 of 5

Enabled

Set this parameter to on to enable “Discrete 2 of 5”.

Standard 2 of 5 Format

This parameter allows you to choose a standard format – either Identicon (6 start/stop bars) or Computer Identics (4 start/stop bars).

Check Digit Verification

The available options for this parameter are Disabled and MOD 10 Check. “Check Digit Verification” uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Set Length L1, Set Length L2, And Set Length L3

Lengths for “Discrete 2 of 5” can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Double-tapping on these parameters displays dialog boxes where you can define the code length that will be recognized by your scanner.

Length Mode

You can chose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length.

Field Size/Char

Refer to page 148 for details.

192WORKABOUT PRO Hand-Held Computer With Windows Mobile 5.0 User Manual

Page 228
Image 228
Psion Teklogix 8100107B user manual Discrete 2, Standard 2 of 5 Format