Chapter 6: Settings
Decoded (Intermec ISCP)
194 WORKABOUT PRO Hand-Held Computer With Windows Mobile 5.0 User Manual
Field Size/Char
Refer to page148 for details.
6.25.3.19 PDF-417
Enabled
Set this parameter to on to enable “PDF-417”.
Field Size/Char
Refer to page148 for details.
6.25.3.20 Micro PDF-417
Enabled
Set this parameter to on to enable “Micro PDF-417”.
Code 128 Emulation
When this parameter is enabled, the scann er transmits data from certain Micro PDF-
417 symbols as if it was encoded in Code 128 symbols.
If Code 128 Emulation is enabled, the following Micro PDF-417 symbols are
transmitted with one of the following prefixes:
]C1 if the first codeword is 903-907, 912, 914, 915
]C2 if the first codeword is 908 or 909
]C0 if the first codeword is 910 or 911
If Code 128 Emulation is set to off, the Micro PDF-417 symbols are transmitted
with one of the following prefixes:
]L3 if the first codeword is 903-907, 912, 914, 915
]L4 if the first codeword is 908 or 909
]L5 if the first codeword is 910 or 911