Chapter 10: Specifications

 

 

 

 

 

 

 

High Capacity–3000 mAh (Model WA3006)

 

 

 

 

 

 

 

 

 

 

 

Description

 

 

Condition

 

Standard

 

 

 

 

 

 

 

 

 

 

 

 

Capacity_2

 

After standard charge, measured the time taken for a

500 minutes or more

 

 

 

standard discharge.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

After standard charge, apply a standard discharge

 

 

 

Over discharge

 

followed by a standby discharge. Then measured

110 minutes or more

 

 

capacity after carrying out standard charge and then a

 

 

 

 

 

 

 

 

 

 

 

 

fast discharge.

 

 

 

 

Self discharge

 

After a standard charge, keep battery at 25°C for 30

100 mins or more

 

 

days. Measure the time taken for a fast discharge.

 

 

 

 

 

 

 

 

 

 

 

 

Perform a standard charge and fast discharge at 0°C,

100 mins. @ 0°C

 

 

Temperature

 

25°C and 40°C and measured the time taken for a

110 mins. @ 23°C

 

 

 

 

 

fast discharge at 25°C.

 

105 mins. @ 40°C

 

Temp./Humidity

 

After standard charge, carry out 5 cycles of the fol-

 

 

 

 

lowing: 65°C and 90% humidity for 8 hrs.

100 minutes or more

 

 

cycle

 

25°C and 65% humidity for 4 hrs.

 

 

 

 

 

 

 

 

 

 

-20°C for 8 hrs. 25°C and 65% humidity for 4 hrs.

 

 

 

 

 

 

 

After standard charge, keep the battery at 60°C for 8

 

 

 

 

Dry heat

 

hrs. Carry out a fast discharge, standard charge and

100 minutes or more

 

 

 

then a fast discharge, measured the time taken for the

 

 

 

 

 

 

 

 

 

 

 

 

second discharge.

 

 

 

 

 

 

 

 

EN61000-4-8:

 

 

 

 

Electro-Static Dis-

 

A. Contact Discharge:+/- 8kV for each contact pad

No damage

 

 

charge

 

by 10 times.

 

 

 

 

 

 

 

 

 

 

 

 

B. Air Discharge:+/- 15kV for 10 times.

 

 

 

10.4.2.3

Environmental Test

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description

 

Test Reference

 

Test Condition/Result

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drop sample battery on all faces from

 

 

 

 

Drop

 

(mechanical)

 

height of 1.2 meters onto concrete floor

 

 

 

 

 

No explosion, fire, vent, leakage and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

open circuit voltage higher than 3.7V.

 

 

Storage at high temp.

EN60068-2-2 Test

 

+60°C dry for 240 hours

 

 

 

 

No explosion, fire, vent or leakage.

 

 

 

 

 

 

 

 

 

 

 

Storage at low temp.

EN60068-2-1 Test

 

-20°C dry for 240 hours

 

 

 

 

No explosion, fire, vent or leakage.

 

 

 

 

 

 

 

 

 

 

 

Storage at high temp.

IEC68-2-3 Test

 

+40°C at 90%RH for 240 hours.

 

 

 

 

and humidity

 

 

No explosion, fire, vent or leakage.

 

 

 

 

 

 

 

 

WORKABOUT PRO Hand-Held Computer With Windows Mobile 5.0 User Manual 343

Page 379
Image 379
Psion Teklogix 8100107B user manual 10.4.2.3