WORKABOUT PRO Hand-Held Computer With Windows Mobile 5.0 User Manual 339
Chapter 10: Specifications
Standard Capacity–2000 mAh (Model WA3000-G1)

Battery Pack Electrical Specifications

10.4.1.2 Standard Discharge
Note: Standard charge is defined as charging with constant voltage limit of 4.2V
and constant current limit of 0.9A; the termination charge occurs when
the current drops to 45mA.
Standard discharge is defined as discharging at a constant current of
350mA until the battery protection circuit switches the battery output off in
over-discharge mode.

Acceptance Test Specifications

Discharge Current 0.5C (-20°C to 60°C) Typical
Internal Resistance 150 m Maximum

Description Specification

Minimum Typical Maximum
Over voltage detection voltage 4.325V 4.350V 4.375V
Charge enable 4.10V 4.15V 4.20V
Under voltage detection voltage 2.5V 2.6V 2.7V
Over current detection current 2.97A 3.17A 3.36A
Short-circuit detection current 9.9A 13.33A 16.83A
Short-circuit detection voltage 150mV 200mV 250mV
Over voltage delay time 0.8s 1s 1.2s
Under voltage delay time 90ms 100ms 110ms
Over current delay time 5ms 10ms 20ms
Short-circuit delay time 160µs 200µs 240µs
Recovery charge current 0.5mA 1mA 2mA

Description Condition Standard

Open circuit voltage After standard charge, measured within 24 hours. 4.15V or more
Internal resistance After standard charge, measured within 24 hours. 150 m max.
Capacity_1 After standard charge, measured time taken for a fast
discharge. 110 minutes or more
Description Specification Remark