P. ON DELAY (Power on delay)

Use this function to activate power-on delay.

Turn on the AUTO ID before the following operations.

Example: Setting “ON”

Perform Steps 1-2 of VIDEO WALL, then...

3.Use the and buttons to select “P. ON DELAY”.

4.Use the  and  buttons to select “ON”.

The mode switches as follows each time the  or  button is pressed:

OFF ON

 

 

 

 

 

VIDEO WALL

 

 

 

 

DIVIDER

:

1

 

 

 

POSITION

 

 

 

 

 

DISP. MODE

:

SPLIT

 

 

AUTO ID

:

OFF

 

 

IMAGE ADJUST

 

 

 

 

 

 

P. ON DELAY

 

:

ON

 

 

 

 

 

 

 

 

 

 

PLE LINK

:

OFF

 

 

REPEAT TIMER

:

OFF

 

 

 

 

SEL.

ADJ.

EXIT

RETURN

 

 

 

 

 

 

Information

 

 

 

 

P. ON DELAY settings

ON ...... Turns on the main power of each display after

a delay time.

OFF .... Turns on the main power of all displays at the

same time.

* Once this function has been set to “ON”, POWER ON/

OFF button on the remote control does not function

except for the No.1 monitor.

By pressing the POWER ON button on the remote

control the No.1 monitor will turn on and the others

will be turned on one by one automatically.

* From the second monitor onward, neither the POWER

button on the unit nor the POWER ON button on the

remote control does function. However, by pressing and

holding the POWER ON button for more than 3 seconds,

PLE LINK

Use this function to set a uniform brightness for each display.

Turn on the AUTO ID and set the DIVIDER (at 1, 4 or 9) before the following operations.

Example: Setting “ON”

Perform Steps 1-2 of VIDEO WALL, then...

3.Use the and buttons to select “PLE LINK”.

4.Use the  and  buttons to select “ON”, then press the MENU/ENTER button.

The mode switches as follows each time the  or  button is pressed:

OFF ON

 

 

 

 

 

VIDEO WALL

 

 

 

 

DIVIDER

:

1

 

 

 

POSITION

 

 

 

 

 

DISP. MODE

:

SPLIT

 

 

AUTO ID

:

OFF

 

 

IMAGE ADJUST

 

 

 

 

 

P. ON DELAY

:

OFF

 

 

 

PLE LINK

 

:

ON

 

 

 

 

 

 

 

 

 

 

REPEAT TIMER

:

OFF

 

 

 

 

SEL.

ADJ.

EXIT

RETURN

 

 

 

 

 

 

Information

 

 

 

 

PLE LINK settings

ON ...... Sets a uniform brightness for each screen in a

video wall.

OFF .... Sets the individual screen brightness for each

screen in a video wall.

*When this function is set “ON”, connect your plasma

displays with the remote cable (optional) in the order of the position numbers for the 22 video wall. See the

drawing below.

*If there are changes in the DIVIDER or POSITION, the PLE LINK will automatically turn OFF.

the monitor will be turned on.

REMOTE IN

REMOTE OUT

No.1 No.2

No.4 No.3

Display 1

No.1 No.2

No.4 No.3

Display 4

REMOTE

OUT

REMOTE IN

REMOTE

OUT

REMOTE IN

No.1 No.2

No.4 No.3

Display 2

No.1 No.2

No.4 No.3

Display 3

REMOTE OUT

REMOTE IN

*With the 33 video wall, connect the final display to the first display the same way as with 22 video wall.

Note: The remote control can be operated unless the IR REMOTE is set to “OFF”.

52

Page 62
Image 62
Runco PL-61CX manual On Delay Power on delay,  P. on Delay settings,  PLE Link settings