5. Maintenance and Troubleshooting

The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or sooner if a noticeable degradation in brightness occurs. Contact your Runco dealer to obtain a replacement lamp.

1.Turn off the projector and unplug the power cord.

Allow the projector to cool down for approximately 45 minutes prior to removing

the lamp assembly for replacement.

2. Loosen the two captive screws from the lamp cover.

3. Remove the lamp cover.

4. Remove the two lamp assembly mounting screws.

5.Grasp the lamp assembly handle and pull gently, removing the lamp module from the projector housing.

6. Install the new lamp module and replace the two screws.

7. Replace the lamp cover at the right side first and secure it with the two screws.

8. Turn on the projector and reset the Lamp Hour counter. To do this, select Lamp Hours Reset from the Display Device - Configure menu. A confirmation dialog box appears. Select “Yes,” then press ENTER to continue with the reset or “No” to cancel the operation.