Appendix

Status Read Command

Format

The command is sent from PC to the projector with the format below;

'CR' [Command] 'CR'

Command: one character (refer to the command table below.

The projector decodes the command and returns the 'Character string' with the format below;

Command

Function

Projector

Projector status

Return

 

 

 

 

 

00

Power On

 

 

80

Stand-by mode

 

 

40

Countdown

 

 

20

Cooling down

 

 

10

Power Malfunction

 

 

28

Cooling down at the temperature anomaly

 

 

24

Cooling down at Power Management mode

CR0

Status Read

04

Power Management mode after Cooling down

21

Cooling down after the projector is turned off when the

 

 

lamps are out.

 

 

81

Stand-by mode after Cooling down when the lamps are out.

 

 

88

Stand-by mode after Cooling down at the temperature

 

 

anomaly.

 

 

 

 

 

2C

Cooling down when the projector is turned off by the shutter

 

 

management function.

 

 

 

 

 

8C

Stand-by mode after cooling down by the shutter

 

 

management function.

 

 

 

 

 

 

%1 = Temperature at Sensor 1 (˚C)

 

 

 

%2 = Temperature at Sensor 2 (˚C)

 

 

 

%3 = Temperature at Sensor 3 (˚C)

CR6

Temperature Read

%1 %2

(ex.) %1 = 12.3˚C, %2 = 23.4˚C, %3 = 34.5˚C

--> The projector displays “12.3 23.4 34.5”

%3

 

 

(For each sensor, two digit and the tenth place numbers

 

 

 

 

 

 

are displayed with a space between each temperature.)

?

Communication failure

The tables on page 96 and 97 show the typical command lists for controlling the projector. Please consult your local dealer for further information of other commands.