(3)To mount the indoor unit on the rear panel.

1.When installing the indoor unit, position the indoor unit onto the installation tabs on the upper part of the rear panel. (Fig. 3-146)

2.Press on the air outlet to hold it in place, and press the lower part of the indoor unit until a “click” sound is heard and the indoor unit is securely fastened to the installation tabs on the lower side of the rear panel. (Fig. 3-147)

Raising the clamp to lift up the indoor unit will facilitate this work. (Fig. 3-148)

To remove the indoor unit, press up on the 2 locations

(marks) on the lower part of the unit frame to disconnect the installation tabs. Refer to Section 3-35. “Removing the Rear Panel from the Unit” (Fig. 3-133).

Then lift up the indoor unit to remove it.

3-40. Shaping the Tubing

Right-rear tubing

(1)Shape the refrigerant tubing so that it can easily go into the hole. (Fig. 3-149)

(2)After performing a leak test, wrap both the refrigerant tubing and drain hose together with insulating tape.

The drain hose should be positioned below the refrigerant tubes, and should be given sufficient space so that no strong tension is applied to it.

K(3) Push the wiring, refrigerant tubing and drain hose through the hole in the wall. Adjust the indoor unit so it is securely seated on the

rear panel.

Left or left-rear tubing

(1)Pass the tubing and drain hose into the rear of the indoor unit. Provide sufficient length for the connections to be made. Next, bend the tubing with a pipe bender, and connect them. (Fig. 3-150)

(2)After performing a leak test, wrap the refrigerant tubing and drain hose together with insulating tape, as shown in the figure at right. (Fig. 3-151)

Then fit the tubing into the tubing storage space in the rear of the indoor unit and clamp in place.

(3)Adjust the indoor unit so that it is securely installed onto the rear panel.

3-41. Installing the Drain Hose

a)The drain hose should be slanted downward to the outside. (Fig. 3-152)

b)Never form a trap in the course of the hose.

c)If the drain hose will run in the room, insulate the hose* so that chilled condensation will not damage furniture or floors.

*Foamed polyethylene or its equivalent is recommended.

WARNING

Do not supply power to the unit or operate

it until all tubing and wiring to the outdoor

 

 

 

unit are completed.

 

62

Installation tabs

Press

Installation tabs

Fig. 3-146

Fig. 3-147

Clamp

Fig. 3-148

Rear panel tab

Insulating

tape

Refrigerant

tubing

 

Indoor and

Plastic cover

outdoor unit

connection wiring

 

Fig. 3-149

Insulation

Fig. 3-150

Refrigerant tubing

Insulating tape

Rear panel

Inter-unit wiring

Drain hose

Fig. 3-151

Indoor unit

Slant

Refrigerant tubing

Fig. 3-152

W-3WAY_ECO-i_US.indd 62

2008/02/07 10:56:03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 62
Image 62
Sanyo CHDZR09053, XMHX1252 Shaping the Tubing Right-rear tubing, Left or left-rear tubing, Installing the Drain Hose