Sanyo 85464369098000, XMHX1252 How to carry out power supply wiring, Check local electrical codes

Models: XMHX1852 CHDZR09053 XMHX1252 85464369098000 CHDZR14053

1 106
Download 106 pages 6.26 Kb
Page 59
Image 59

Never allow traps to occur in the course of the piping.

Insulate any piping inside the room to prevent drip- ping.

After the drain piping, pour water into the drain pan to check that the water drains smoothly.

If the drain hose is to be raised, use the optional drain up kit.

The drain hose can be raised 23-5/8" above the top of the main unit. (For details, refer to the manual of the

optional part.)

Drain port

 

* If the drain hose is

Screwdriver

routed through the

 

left side, refer to Fig.

 

3-127, and follow the

Rubber stopper

procedure above to

 

install the hose. Re-attach the rubber stopper that was earlier removed onto the right side.

The rubber stopper can be inserted easily by using a screwdriver or similar tool to press the stopper into the drain port on the main unit. Press the stopper into the main unit drain port as far as it will go.

How to carry out power supply wiring

(1) Wiring connection ports

The power inlet ports are located at the rear and top. The remote controller wiring inlet ports are located at the rear and top (for use with the wired remote controller).

For details, refer to Fig. 3-126. For the method used to insert the wiring, refer to the figure below. (Fig. 3-132)

CAUTION When removing the fastening bracket from the cover of the

electrical component box, use caution to avoid dropping the bracket.

 

 

 

 

 

 

Twist tie

 

 

 

 

 

 

 

 

 

 

(4 ties)

 

 

Hard PVC pipe

 

 

 

 

 

 

 

 

Drain hose

 

 

Position to

Unit drain port

 

 

 

(equivalent to

 

insulation

 

 

 

 

 

 

 

 

 

 

 

VP-20)

fasten hose

 

 

 

 

 

 

 

(supplied)

 

 

 

 

 

 

 

 

 

 

 

(Field supply)

bands

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drain hose

 

(supplied)

13/64

13/64

63/64

63/64

5-33/64

Hose band

Unit drain pan

(2 bands, supplied)

Unit: in.

 

Fig. 3-131

CAUTION

Check local electrical codes

and regulations before wir-

 

 

ing. Also, check any specified

 

instruction or limitations.

T

(2) How to carry out wiring

Open the knock-out hole on the rear or top of the main unit. Attach the supplied rubber grommet and pull the power wiring into the main unit.

Feed the wiring into the wiring inlet port on the electrical component box. Connect the wiring to the terminal plate and fasten in place with the supplied clamp.

Perform electrical and grounding work in accordance with the package A/C power specifications, and following local electrical codes and regulations.

Inter-unit control wiring

ø1-9/32 knock-out

Eyelet (supplied)

Power supply outlet

Fig. 3-132

59

W-3WAY_ECO-i_US.indd 59

2008/02/07 10:56:02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 59
Image 59