Sanyo 85464369098000, XMHX1252, XMHX1852, CHDZR09053 Taping the Tubes, Finishing the Installation

Models: XMHX1852 CHDZR09053 XMHX1252 85464369098000 CHDZR14053

1 106
Download 106 pages 6.26 Kb
Page 79
Image 79

6-4. Taping the Tubes

(1)At this time, the refrigerant tubes (and electrical wir- ing if local codes permit) should be taped together with armoring tape in 1 bundle. To prevent the con- densation from overflowing the drain pan, keep the drain hose separate from the refrigerant tubing.

(2)Wrap the armoring tape from the bottom of the out- door unit to the top of the tubing where it enters the wall. As you wrap the tubing, overlap half of each previous tape turn.

(3)Clamp the tubing bundle to the wall, using 1 clamp approx. each ft. (Fig. 6-10)

NOTE

Do not wind the armoring tape too tightly since this will decrease the heat insulation effect. Also ensure that the condensation drain hose splits away from the bundle and drips clear of the unit and the tubing.

6-5. Finishing the Installation

After finishing insulating and taping over the tubing, use sealing putty to seal off the hole in the wall to prevent rain and draft from entering. (Fig. 6-11)

79

Clamp

Insulated tubes Drain hose

Fig. 6-10

Apply putty here

Tubing

Fig. 6-11

W-3WAY_ECO-i_US.indd 79

2008/02/07 10:56:10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 79
Image 79
Sanyo 85464369098000, XMHX1252, XMHX1852, CHDZR09053, CHDZR14053 Taping the Tubes, Finishing the Installation