7) Field data transmission

Designates printing data of the field.

Field data can be designated up to a maximum of 50 fields.

<D> [1 Bh, 44h] DD nnn…..

 

 

Field

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

No.

 

 

 

Printing data (Unused place can be omitted)

S

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

N

N

1

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

Special remark on field data transmission.

I.Bar code with start/stop code (NW-7, CODE 39)

For NW-7, CODE39 barcode, set [Data digits number] excluding start/stop field in parameter setting.

Transmit additional 2 data as shown when using online.

II. CODE 128, UCC/EAN 128 bar code.

These are barcodes of similar symbology, but are classified as different bar code types due to there are symbols that cannot be input manually. In online printing, CODE128A set (not available in stand alone) can be utilized in data transmission including start symbol and function symbol.

Remarks on CODE128:

1:Designate CODE 128 B set for field parameter.

2:Refer to appendix on data character for CODE128.

3:Maximum data is 40 digits/field.

4:Start code cannot be omitted.

5:Stop code, Modulus 103C/D are automatically added.

III. Calendar field

Date, time printing field utilizes printer internal calendar. As a result, transmission of printing data is not necessary. In utilization of adding function for date and time, transmit data with date addition (3 digits) and time addition (2 digits).