SATO DR300 manual Ready/Busy

Models: DR300

1 96
Download 96 pages 806 b
Page 79
Image 79

DR300 Operator Manual

Chapter 10 - Serial Interface

 

 

Ready/Busy

This is the hardware flow control for the serial interface on the DR printers. By raising/lowering the voltage level on Pin 20 of the RS232 port, the printer notifies the host when it is ready to receive data. Pin 40 (RS) and Pin 20 (DR) are the important signals on the printer for this method of flow control. The host must be capable of supporting this flow control method for it to function properly. The selection of 1 item or multi items print buffer can be set by DIP switch.

Data stream (ESC + “A” ~ ESC + “Z”) from host might not be fully received by printer under the following conditions:

Printer is in printing process during Single Job Buffer Mode.

Printer is engaged with error condition.

1 : Cable connection

 

Host

Printer

FG

 

1 FG

 

RD

2 SD

SD

3 RD

CS

4 RS

RS

5 CS

ER

6 DR

SG

 

7 SG

 

DR

20 ER

2 : Input/Output signal explanation

Pin No.

Signal

Direction

Content

 

Name

 

 

1

F G

-

Frame ground

2

S D

Output

Data transmitted from printer to host

3

R D

Input

Data transmitted from host to printer

4

R S

Output

“Low” level when error occurs in printer

5

C S

Input

Always hold “High”

6

D R

Input

Always hold “High”

7

S G

-

Signal ground

20

E R

Output

“High” when printer is ready to receive data

 

 

 

“Low” when various errors occur, when the printer is

 

 

 

offline, and while printing in the Single Job Buffer

 

 

 

Mode. It will also go “Low” when the data in the

 

 

 

buffer reaches the Buffer Near Fall Level

77

Page 79
Image 79
SATO DR300 manual Ready/Busy