Chapter 9 - Online Programming

 

 

 

 

 

 

 

 

Data Code

 

 

 

 

 

 

 

 

 

 

Digit

Designated Item

 

Designated Description

 

 

Position

 

 

 

 

 

1

Field Designation

4

: 2D Bar Code

 

 

2

Field Designation

1

: Data Code

 

 

3

Mode

1

: Numeric Mode

 

 

 

(Format ID)

2

: Alpha (upper case mode)

 

 

 

 

3

: Alphanumeric & Notation

 

 

 

 

4

: Alphanumeric

 

 

 

 

5

: 7-bit data

 

 

 

 

8-bit data mode (*refer to code table)

 

 

4, 5

Vertical Position

0000: Input only and no printing field

 

 

6, 7

 

0001 ~ 2848: Vertical position (dot)

 

 

8, 9

Horizontal Position

001 ~ 640: Horizontal position (dot)

 

 

10

 

 

 

 

 

11

Rotation

0

: 0º

 

 

 

 

1

: 90º

 

 

 

 

2

: 180º

 

 

 

 

3

: 270º

 

 

12, 13

Module

01 ~ 32 : Cell Size (dot)

 

 

 

 

(refer to module size notes)

 

 

14, 15

Reserved

00

 

 

16, 17

Error Correction

Error Correction Level

 

 

 

 

00 : ECC000, 05 : ECC050, 08 : ECC080

 

 

 

 

10 : ECC100, 14 : ECC140, 20 : ECC200

 

 

18

Reserved

[0] Fixed

 

 

19 ~

Reserved

All [0]

 

*Module

To define the cell size:

1.The definition of 01, 02 dots are acceptable but may face difficulties for decoding/reading.

2.Use larger module for better printing quality.

Error Correction

To define the error correction level when barcode is damaged or tampered. Connection level is high with larger correction definition.