SATO DR300 manual OFF Status XON-OFF

Models: DR300

1 96
Download 96 pages 806 b
Page 91
Image 91

 

DR300 Operator Manual

Appendix A

 

 

 

 

 

 

 

Separate sheet 1 (Parity setting)

 

 

 

2

3

Content

 

 

ON

ON

(Reserved)

 

 

ON

OFF

Odd

 

 

OFF

ON

Even

 

 

OFF

OFF

None

 

 

Separate sheet 2 (Baud rate setting)

 

 

5

6

Content

 

 

ON

ON

2400 bps

 

 

ON

OFF

4800 bps

 

 

OFF

ON

19200 bps

 

 

OFF

OFF

9600 bps

 

 

Separate sheet 3 (Protocol setting)

 

 

7

8

Content

 

 

ON

ON

(Reserved)

 

 

ON

OFF

STATUS 3

 

 

OFF

ON

XON-OFF

 

 

OFF

OFF

Ready/Busy

 

 

DIPSW 2

 

 

 

No.

Setting

Content

 

 

1

ON

Direct Thermal

 

 

 

OFF

Thermal Transfer

 

 

2

ON

(Reserved) / Reflecting type sensor

 

 

 

OFF

(Reserved) / See through type sensor

 

 

3

ON

Head Check, Yes

 

 

 

OFF

Head Check, No

 

 

4

ON

Hex dump function, Yes

 

 

 

OFF

Hex dump function, No

 

 

5

ON

Multi items receive mode

 

 

 

OFF

1 item receive mode

 

 

6

ON

(Reserved)

 

 

 

OFF

(Reserved)

 

 

7

ON

Size detection, Yes

 

 

 

OFF

Size detection, Yes

 

 

8

ON

Tear off (Dispense), Yes

 

 

 

OFF

Tear off (Dispense), No

 

*Pitch sensor (DSW2-2) is effective only during service, test print. It is void during test print.