2 : Input Check Designation (Bar Code)
•Bar code without human interpretation character.
•Bar code with human interpretation character,
Digit | Designated Item | Designated Description |
Position |
|
|
18, 19, 20 | Bar code height | 001~600 : bar code height (dot) |
21 | Reserved | 0 |
22 | Sequential | 0 : No |
| function | 1 : Increment |
|
| 2 : Decrement |
23, 24 | Start Position | 01~40 : Starting Position |
25, 26 | Data Count | 01~08 : data count |
27, 28, 29 | Step (increase, | 001~999 : sequential step |
| decrease) |
|
30, 31 | Repeat quantity | 01~99 : same number repeat quantity |
Minimum data | 00000001 ~ 99999999 | |
| range | For incremental numbering, the wrap around value |
|
| when it reaches the maximum value. |
|
| For decrement numbering, the minimum value. |
Maximum data | 00000001 ~ 99999999 | |
| range | For incremental numbering, the maximum value. |
|
| For decrement numbering, the wrap around value |
|
| when it reaches the minimum value. |
*Sequential numbering is for numeric data only.
12)Line / Box Field Transmission
Digit | Designated Item | Designated Description |
Position |
|
|
1, 2 | Field designation | 80 : Line /Box, Graphic, Reverse |
3 | Font Type | 0 : Line / Box |
4~7 | Vertical Position | 0001~1424 : Vertical position (dot) |
8~10 | Horizontal Position | 001~640 : Horizontal position (dot) |
11~14 | Vertical Line Length | 0001~1424 : Vertical line length (dot) |
15~17 | Horizontal Line | 001~640 : Horizontal line length (dot) |
| Length |
|
18 | Horizontal Width | |
19 | Vertical Width | |
20~47 | Reserved | 0 : Reserved |