DR300 Operator Manual | Chapter 9 - Online Programming |
|
|
¾Input check designation (Normal) 1 Normal, alphanumeric character
Digit | Designated |
| Designated Description |
Position | Item |
|
|
18 | Input check 1 | 0 : when online mode | |
19 | Input check 2 | 0 : when online mode | |
20 | Bold Font | 0 : None | |
|
| 1 | : Right |
|
| 2 | : Lower |
|
| 3 | : Right & Lower |
21 | Reserved | 0 |
|
¾Sequential numbering
1 Normal, alphanumeric character
Digit | Designated Item | Designated Description |
Position |
|
|
22 | Sequential function | 0 : No |
|
| 1 : Increment |
|
| 2 : Decrement |
23, 24 | Start Position | 01~40 : starting position |
25, 26 | Data Count | 01~08 : data count |
27, 28, | Step (increase, decrease) | 001~999 ; sequential step |
29 |
|
|
30, 31 | Repeat quantity | 01~99 : same number repeat quantity |
Minimum data range | 00000001~99999999 : | |
|
| For incremental numbering, the wrap |
|
| around value when it reaches the |
|
| maximum value. |
|
| For decrement numbering, the minimum |
|
| value. |
Maximum data range | 00000001~99999999 | |
|
| For incremental numbering, the |
|
| maximum value. |
|
| For decrement numbering, the wrap |
|
| around value when it reaches the |
|
| minimum value. |
* Sequential numbering is for numeric data only.
56