DR300 Operator Manual

Chapter 9 - Online Programming

 

 

¾Input check designation (Normal) 1 Normal, alphanumeric character

Digit

Designated

 

Designated Description

Position

Item

 

 

18

Input check 1

0 : when online mode

19

Input check 2

0 : when online mode

20

Bold Font

0 : None

 

 

1

: Right

 

 

2

: Lower

 

 

3

: Right & Lower

21

Reserved

0

 

¾Sequential numbering

1 Normal, alphanumeric character

Digit

Designated Item

Designated Description

Position

 

 

22

Sequential function

0 : No

 

 

1 : Increment

 

 

2 : Decrement

23, 24

Start Position

01~40 : starting position

25, 26

Data Count

01~08 : data count

27, 28,

Step (increase, decrease)

001~999 ; sequential step

29

 

 

30, 31

Repeat quantity

01~99 : same number repeat quantity

32-39

Minimum data range

00000001~99999999 :

 

 

For incremental numbering, the wrap

 

 

around value when it reaches the

 

 

maximum value.

 

 

For decrement numbering, the minimum

 

 

value.

40-47

Maximum data range

00000001~99999999

 

 

For incremental numbering, the

 

 

maximum value.

 

 

For decrement numbering, the wrap

 

 

around value when it reaches the

 

 

minimum value.

* Sequential numbering is for numeric data only.