8.1.4 STS event table

Network

Management Card

User Manual

<Sensor name>: Humidity is in normal

<Sensor name>: L'humidité est revenue à un

range

niveau normal

<Sensor name>: <Input #1 label>

<Sensor name>: <Input #1 label> <when

<when closed label>

closed label>

<Sensor name>: <Input #1 label>

<Sensor name>: <Input #1 label> <when open

<when open label>

label>

<Sensor name>: <Input #2 label>

<Sensor name>: <Input #2 label> <when

<when closed label>

closed label>

<Sensor name>: <Input #2 label>

<Sensor name>: <Input #2 label> <when open

<when open label>

label>

8.1.4 STS event table

English

French

Source 1 Static Switch fault

Défaut Contacteur Statique source 1

KM1 fault

Défaut Contacteur source 1 (KM1)

Source 2 Static Switch fault

Défaut Contacteur Statique source 2

KM2 fault

Défaut Contacteur source 2 (KM2)

Source 1 voltage fault

Défaut tension source 1

Source 1 frequency fault

Défaut frequence source 1 hors tolerances

Source 2 voltage fault

Défaut tension source 2

Source 2 frequency fault

Défaut frequence source 2 hors tolerances

Load not powered

Charge non alimentée

Transfert forbiden

Transfert interdit

Displacement source 1 / source 2

Déphasage sources 1 / 2

EPO present

Défaut arrêt d'urgence activé

Thermal overload

Défaut surcharge thermique

Overload fault

Défaut surcharge

Internal failure

Défaut interne

General alarme

Défaut Alarme Générale

Communication failure

Défaut Communication interne

Source 1 circuit breaker (Q1) closed

Interrupteur Q1 fermé

Source 1 circuit breaker (Q1) open

Interrupteur Q1 ouvert

Source 2 circuit breaker (Q2) closed

Interrupteur Q2fermé

Source 2 circuit breaker (Q2) open

Interrupteur Q2ouvert

Output circuit breaker (Q3) closed

Interrupteur Q3fermé

Output circuit breaker (Q3) open

Interrupteur Q3ouvert

Source 1 bypass switch (Q1BP) closed

Interrupteur Q1BP ferme

Source 1 bypass switch (Q1BP) open

Interrupteur Q1BP ouvert

Source 2 bypass switch (Q2BP) closed

Interrupteur Q2P ferme

Source 2 bypass switch (Q2BP) open

Interrupteur Q2P ouvert

Source 1 active

Source 1 active

Source 2 active

Source 2 active

Source 1 preferred

Source 1 prioritaire

Source 2 preferred

Source 2 prioritaire

Tranfer available

Transfert autorisé

<Sensor name>: Temperature is below

<Sensor name>: La température est en

low threshold %d °C

dessous du seuil bas %d °C

<Sensor name>: Temperature is

<Sensor name>: La température est au

above high threshold %d °C

dessus du seuil haut %d °C

<Sensor name>: Temperature is in

<Sensor name>: La température est revenue à

Network Management Card – User Manual

34003676EN/HA

Page 76/81