Introduction

DART 300 Modem

Protocol. Selection of UDP or TCP is important to determining the best configuration for controlling the opening and closing of sessions, maintaining data integrity over large file transfers, and keeping network overhead low.

Security. Implementation of the Friends Only feature will depend on the client/server relationship and whether or not the central host will always use the same IP address. If there is concern about improper access to the field device, and the DART 300 / local host can act as a client, then the registration process could be handled manually. This means the local unit is only connected to the network when it is ready to contact the remote host.

Power Consumption. If there are concerns about the amount of power available in the field locations, use of the modem’s sleep modes may be needed. If the local host is capable of sleeping, the implementation of the Ring Indicator (RI) signal from the modem can be used to control host wake-ups.

To fully understand the options made available by the DART 300, the system designer should read the Feature Reference sections (4 through 7) of this manual.

During this first stage, planning may also be needed to resolve the physical installation issues of power supply, antenna installation and grounding, and cabling. A review of the Installation sections (10 and 11) will prepare you for these issues.

2.2.2.Stage 2 – Bench Integration and Testing

Before installation in the field, the DART 300 requires configuration and testing. One or two units should be set-up on the test bench and connected to the CDPD network and a PC or terminal device. Following configuration, the modem must be connected to the target host device and tested.

There are several steps to this testing:

1.Physical connection to: a power supply, a host PC, and an antenna with access to CDPD coverage.

2.Initial configuration for activation on the CDPD network. This step will test that the modem can connect to, and register with, the CDPD network, and respond to a PING.

3.Configuration for use with the local host device. This configuration is performed with a terminal (PC) to prepare the modem for use with the target device.

4.Connection and test with the local host device. This may involve different serial cabling if the local host is configured as a DCE device. This step tests that the device will work with the modem and communicate over the network to the monitoring system. Extensive testing of fault tolerance should be performed to ensure that problems in the field are self-correcting or can be corrected remotely.

The first two steps above are covered in Section 3, Getting Started. The configuration and testing with the target device should happen after reading the balance of this guide.

2.2.3.Stage 3 – Field Installation and Testing

Before configuring and installing many units, it is advisable to install one or two field units to verify power connection and consumption, antenna installation and network coverage, connectivity, and end-to-end performance. Only when this stage passes should you rollout the full system.

Custom power connectors, data cables, and mounting hardware may be required for the field installation. This step allows you to verify that the connections are working and the system functions as required.

2.2.4.Stage 4 – Rollout

This involves configuring many DART 300 units. Each must have the same configuration as the units that passed the field trial; except the CDPD activation (NEI) will be different for each unit. Depending on the scale of the system, this can be done by hand or through an automated script.