Environmentalrequirement Parameter
Storagetemperature -4°Fto 140°F (-20°Cto 60°C)
Humidity 5% to 80% relativehumidity, non-condensing
Ventilation Maintaina 4" (10 cm) ventilation areaaroundy ourinteractive flat
panelto enable its cooling fans to operate.Do not st oreor
operateyour interactivef lat panelin dusty environments
becausedust could interferew ith the product’sv entilationand
cooling.
Waterand fluid resistance lIntended for indooruse only. Doesn’t meet any salt-spray
orwater ingress requirements.
lDon’t pouror spray liquids directly onto the interactive flat
panelor any of its s ub-components. These liquidsmight
getinto areas where they could damagesensitive
electroniccomponents. Refer to page 56for detailed
instructionson cleaning your interactive flat panel.
Wall-mounting your interactive flat panel
Use a team of trained,professional installers to install your interactive flat panel.
WARNING
lImproperinstallation can resultin personal injury or productdamage.
lYourinteractive flat panel weighs 98 lb. (44.5k g). Refert o local buildingcodes to ensure your
installationarea can supportthis weight.
CA U T I O N
Do not allow the weight of the interactivef lat panelto rest on the color select module becauseit is
notdesigned to supportproduct weight.At tachother componentswhile the interactive flatpanel is
eitherstill in its packagingor suspended froma lif ting device to preventthe weight of the interactive
flat panelfrom damagingthe color select module.
IM P O R T A N T
lSaveall product packagingso that it is availableif you need totransport yourinteractive flat
panel.If youroriginal packagingis not available, you can purchasenew product packaging
fromy ourauthorizedS MART reseller(smarttech.com/where).
CH A P T E R 2
Installingyour interactiveflat panel
10