L
ONG
-R
EACH
E
THERNET
C
OMMANDS
29-19
The transceiver will adjust its transmitted signal to conform to the
power limitations set by the lre pbo-config command.
If upstream power backoff is enabled with the lre upbo command
(page 29-19), the transceiver will automatically reduce the PSD at each
frequency breakpoint set the by the lre psd-breakpoints (page 29-12)
and lre psd-frequencies (page 29-13) commands.
Example
This example sets PSD values for downstream bands at 0 -60 -60 -60 0 0
dBm/Hz, and for upstream bands at 0 -11.2 -7.419 -7.419 0 0 dBm/Hz.
Related Commands
lre upbo (29-19)
show lre pbo-config (29-69)
lre psd-breakpoints (29-12)
lre psd-frequencies (29-13)
lre upbo
This command enables upstream power backoff. Use the no form to
restore the default setting.
Syntax
[no] lre upbo
Default Setting
disabled
Command Mode
Global Configuration
Interface Configuration (VDSL Port)
Console(config)#
Console(config)#lre pbo-config k1[0] 0 k1[1] -60000 k1[2] -60000
k1[3] -60000 k1[4] 0 k1[5] 0 k2[0] 0 k2[1] -11200 k2[2] -7419
k2[3] -7419 k2[4] 0 k2[5] 0
Console(config)#