D
ISPLAYING
VDSL I
NFORMATION
29-81
Example
show lre rate-info
This command displays rate information for the VDSL line.
Syntax
show lre rate-info [unit/port]
unit - Stack unit. (Range: 1)
port - Port number. (Range: 1-16)
Command Mode
Privileged Exec
Console#show lre phys-info 1/1
port 1/1 Phys info:
Phys current line rate : 71680 kpbs
Phys current attainable rate : 72064 kpbs
Phys current output power : 7.7 dbm
Phys current atn : 1.4 dbm
Console#
Table 29-11 show lre phys-info - display description
Field Description
Phys current line rate Current data rate in steps of 1000 bits/second.
Phys current attainable rate Maximum currently attainable data rate in steps of
1000 bits/second.
Phys current output power Measured total output power transmitted by this
VDSL port.
Phys current atn Measured difference in the total power transmitted
by the peer VTU (VDSL Transceiver Unit) and the
total power received by this VTU.