VDSL C
OMMANDS
29-92
Example
Console#show cpe-info 1/1
Protocol ID: Ikanos EOC Protocol
Protocol Version - Major: 01
Protocol Version - Minor: 01
Vendor ID (Value): ffffffff (HEX), -1 (DECIMAL)
Host Application Version: 7.2.5r7IK104012
BME Firmware Version: Firmware-VTU-R:7.2.5r7 Time May 19 2006,
RTOS Nucleus
AFE Hardware Version: AFE<num: ver> <--:-->
IFE Hardware Version: IFE<num:Dev.Rev> <0:a10>
Firmware Number: 2
Active Version: 2
verId 1: NULL
verId 2: 104012IK7.2.5r9
CO Firmware Buffer is empty now
Console#

Table 29-15 show cpe-info - display description

Field Description
Protocol Manufacturer ID, version numbers, and vendor ID
Host Application Version Primary application firmware version
BME Firmware Version Burst Mode Engine (DSP) firmware version
AFE Hardware Version Analog Front End (DA/AD converter) hardware
version
IFE Hardware Version Integrated Front End (Port VDSL filtering) hardware
version
Firmware Number The number of firmware versions stored in this device.
Active Version The firmware version currently in used by this device.
verId The identifiers for the stored firmware versions.
CO Firmware Buffer Status of the firmware download buffer.