State Industries SUF-100-250, SUF-60-120 instruction manual Status Icons, Description

Models: SUF-60-120 SUF-100-250

1 80
Download 80 pages 61 Kb
Page 45
Image 45
Status Icons

Status Icons

The Status Icons are displayed on the Desktop screen and convey operational and diagnostic information. The icons are described in the table below. See Figure 56 on page 44 and the Sequence Of Operation on page 58.

Table 11

Icon

Description

 

 

Water temperature in the tank has fallen. Shaded area of the animated thermometer icon will rise and fall in response to

 

 

water temperature in the storage tank as sensed from the Upper and Lower Temperature Probes. See beginning on page 8

 

 

and Figure 5 on page 10 for location of Temperature Probes.

 

 

 

 

 

Water temperature in the tank has reached the Operating Set Point. The control system enters the Standby mode.

 

 

 

 

 

The control is unable to initiate a heating cycle. This will happen whenever a Fault condition is detected by the control system

 

 

or when the Enable/Disable circuit is an open circuit. For more information see Enable/Disable Circuit on page 41.

 

 

 

 

 

The Combustion Blower is being energized.

 

 

 

 

 

The Blower Prover pressure switch contacts have closed. The check mark icon is visual confirmation of contact closure. See

 

 

beginning on page 8 for Blower Prover Switch location.

 

 

 

 

 

 

 

 

The Hot Surface Igniter is being energized. See Figure 2 on page 7 for Hot Surface Igniter location.

 

 

 

 

 

The igniter has been energized and the control system has sensed the required minimum igniter current. The check mark

 

 

icon is visual confirmation of minimum igniter current. See the Sequence Of Operation on page 58 for minimum current (AC

 

 

amps) information.

 

 

 

 

 

 

OFF

The 24 Volt Gas Valve is being energized.

GAS Icon ON

The control system has sensed flame at the Main Burner from the flame sensor. See the Sequence Of Operation Flow Chart on page 59 and Figure 2 on page 7.

The control system has declared a Fault condition and must be inspected/serviced by a Qualified Service Agent. Fault message details can be viewed in the Current Fault menu. Heating operation is disabled (lock out) until the condition that caused the Fault is corrected. Power to the water heater must be cycled off and on to reset the control system.

Note: Cycling power will not reset the control system if the condition that caused the Fault has not been corrected.

The control system has declared an Alert condition and must be inspected/serviced by a Qualified Service Agent. The water heater will continue to operate during an Alert condition.

45

Page 45
Image 45
State Industries SUF-100-250, SUF-60-120 instruction manual Status Icons, Description