State Industries SUF-60-120 Water Heater Installation, Condensate Trap Detail, Installation Notes

Models: SUF-60-120 SUF-100-250

1 80
Download 80 pages 61 Kb
Page 38
Image 38
Water Heater Installation

Water Heater Installation

Condensate Drain Installation

Installation must conform with these instructions and local building codes.

Field supplied materials required for installation include:

Approved PVC cement and PVC primer.

1/2 inch PVC pipe - minimum length to equal the distance between the water heater and a suitable building drain.

1/2 inch PVC fittings (elbows and couplings) necessary to install a condensate drain line between the Condensate Drain Trap Assembly and a suitable building drain.

Floor mounted standoffs to brace the drain line.

Installation Notes

1.The condensate drains from the water heater’s covered by this instruction have PH levels between 4.3 and 5.0. Install a commercially available neutralizing kit if required by local codes. Lower PH levels are acidic. Do not connect a metal condensate drain line, such as copper pipe, to the water heater for this reason.

2.The field installed condensate drain line must not be less

than 1/2 inch PVC in size.

3.Do not remove, modify or alter the factory condensate trap.

Installation Instructions

1.Ensure the water heater’s on/off switch is in the “off” position.

2.Install a 1/2 inch PVC condensate drain line between the condensate drain connection on the Condensate Drain Trap and a suitable building drain, see Figure 50 and Figure 51.

3.Terminate the condensate drain piping with an elbow above the drain. Ensure that any discharge will exit the condensate drain line no more than 6 inches (15.2 cm) above a suitable building drain, or external to the building, see Figure 50.

Note: In cold climates it is recommended the condensate drain be terminated at a suitable drain inside the building.

4.Ensure the condensate drain line is not elevated above the condensate drain connection on the trap, see Figure 51.

5.Brace the condensate drain line with floor mounted standoffs every three feet.

6.Ensure the condensate drains freely during start up, see

Start Up on page 52.

EXHAUST (VENT) ELBOW

 

CONDENSATE DRAIN

 

LINE - FIELD INSTALLED

CLEANOUT PLUG SHOULD

DRAIN LINE TO

FACE TOWARDS THE FRONT

OF THE WATER HEATER FOR

TERMINATE NO

SERVICE ACCESS

MORE THAN 6

 

INCHES (15.2 cm)

 

ABOVE DRAIN

FACTORY INSTALLED

BUILDING

CONDENSATE TRAP

DRAIN

Figure 50

PVC PIPE NIPPLE

PVC BUSHING

½” PVC 90° ELBOW

½” NPT

1 ½” SLIP x ½” SLIP

CONDENSATE DRAIN

PVC TEE FITTING

 

CONNECTION. FIELD

1 ½” SLIP x 1 ½” SLIP x ½” NPT

 

INSTALLED DRAIN

 

 

LINE CONNECTS HERE

PVC BUSHING

 

 

1 ½” SLIP x 1 ¼” NPT

 

 

PVC PIPE PLUG

 

½” PVC PIPE NIPPLE

 

½” PVC 90°

1 ¼” NPT

 

CLEANOUT PIPE

 

STREET ELBOW

 

 

PLUG SHOULD

 

 

BE ORIENTED TO

 

 

THE FRONT OF THE

 

 

WATER HEATER FOR

 

 

SERVICE ACCESS

 

 

CONDENSATE TRAP DETAIL

 

Figure 51

38

Page 38
Image 38
State Industries SUF-60-120, SUF-100-250 Water Heater Installation, Condensate Trap Detail, Condensate Drain Installation