Sterling Plumbing 882.00254.00 specifications 50D Plus or 7/50D Controller Configurable Settings

Models: 882.00254.00

1 91
Download 91 pages 60.87 Kb
Page 75
Image 75

Name

Description

Options

Default

Conveying Options

 

 

 

Assigned to pump n

Number (address) of the pump to which this

0–7 (0 = not

0

 

station’s vacuum line is connected.

assigned)

 

 

No more than 20 stations can be assigned to

 

 

 

one pump.

 

 

Volume fill

When this option is enabled, the station’s

disabled,

disabled

 

vacuum valve closes when material covers the

enabled

 

 

station’s proximity sensor or the convey time

 

 

 

elapses, whichever comes first. When disabled,

 

 

 

the station’s vacuum valve remains open until

 

 

 

the convey time has elapsed.

 

 

 

Enable this option for volume-fill stations and

 

 

 

disable it for time-fill stations.

 

 

Special convey

When this option is enabled, the station’s

disabled,

disabled

 

vacuum valve remains open for the convey

enabled

 

 

time, even if the station is not demanding

 

 

 

material and is indicating that it is full. When

 

 

 

disabled, the station’s vacuum valve opens

 

 

 

when there is demand from the station, and it

 

 

 

remains open until the convey time has elapsed

 

 

 

or material trips the volume-fill proximity switch.

 

 

 

Enable this option if and only if the station has

 

 

 

no flapper.

 

 

Alarm Options

 

 

 

No convey

When this option is enabled, the controller

disabled,

disabled

 

issues a “no convey” alarm if it has repeatedly

enabled

 

 

attempted to convey material to the station but

 

 

 

the flapper never opened during the dump

 

 

 

delay. (The number of attempts is controlled by

 

 

 

the next setting.)

 

 

 

Usually this option should be enabled. At times,

 

 

 

you may wish to disable it during operation as a

 

 

 

stopgap measure for dealing with an alarm.

 

 

# attempts B4 alarm

Number of attempts before alarm: the number of

1–99

3

 

times the controller will attempt to convey

 

 

 

material to a station before it issues a “no

 

 

 

convey” alarm.

 

 

 

The setting for this option depends on (a) how

 

 

 

much material your injection mold uses to make

 

 

 

each part compared with the capacity of the

 

 

 

receiver and (b) how important it is to keep your

 

 

 

injection mold from running out of material and

 

 

 

shutting down. A higher setting will give you

 

 

 

fewer alarms, at the risk of emptying the

 

 

 

receiver without warning. A lower setting will

 

 

 

give more frequent alarms, at the risk of

 

 

 

disrupting operations unnecessarily.

 

 

7/50D Plus or 7/50D Controller

Chapter 6: Configurable Settings

74

Page 75
Image 75