Transferring Stations to a Standby Pump

If a pump fails, you can transfer all of the controller’s station assignments for that pump to a standby pump. To do this, you must disable (take offline) both the source pump and the standby pump, and the standby pump must have no stations already assigned to it.

The transfer operation at the controller’s touch screen merely changes the pump assignment for every station on the failed pump. It does not transfer any pumps settings for auto shutdown delay, alarms, or blow-back to the standby pump. Mechanical connections must be changed manually.

To transfer stations from a pump to a standby pump:

1.At any screen, touch Pumps.

The Pump Summary screen appears.

2.Both the source pump and the standby pump must be offline. If either pump is any other state, disable it by touching its icon briefly.

The icon becomes black with a gray outline.

3.Move the vacuum hose from the failed pump to the standby pump, and carry out any other mechanical procedures needed to use the standby pump.

4.At the Pump Summary screen, touch and hold the icon for any pump until the Pump n Setup screen appears.

5.At the Pump n Setup screen, touch Transfer Stations To Standby Pump. The Transfer to Standby Pump screen appears:

7/50D Plus or 7/50D Controller

Chapter 4: Operation

66

Page 67
Image 67
Sterling Plumbing 882.00254.00 specifications Transferring Stations to a Standby Pump