The following table explains the status represented by each color at the Station Summary screen.
Color | Label | Description |
Gray outline | Offline | Station is not enabled. The controller ignores any demands or |
|
| alarms. |
Blue | Ready | Station is enabled and idle (full). |
Yellow | Demand | Station requires material. |
Green | Loading | Station is being loaded with material or is dumping material into |
|
| its receiver. |
White | Purging | The material line is being purged of material. |
Light Blue | Dumping | The station is dumping material into its receiver. |
Blue, blinking | Blow Back | Station’s air filter is being cleaned by blowing compressed air |
|
| backward through it. |
Black, blinking | Bypass | Bypass switch at the station has been turned on, disabling the |
|
| station. |
Green, blinking | Priority | Station is in priority convey mode. Its pump will be temporarily |
|
| dedicated to filling it as soon as possible. |
Red, blinking | Alarm | Station is in alarm. |
Red outline, blinking | Critical | Station is in critical alarm. The controller has disabled the station |
|
| until the alarm is cleared. |
Additional basic information about each station (convey time, dump delay, pump assignment, and, if enabled, RPV setting, purge settings, and material proofing) is available at the Station n Operator screen. See p. 61 for details.
Detailed configuration settings for each station are available at the Station n Setup screen. See p. 74 for details.
7/50D Plus or 7/50D Controller | Chapter 4: Operation | 56 |