6-3 Options for Pump Setup

Several of the items in this screen are not setup options but are instead intended for use during operation. These items (hour meter and transferring stations to a standby pump) are described in Chapter 4, “Operation.”

Name

Description

Options

Default

Idle Time Options

 

 

 

Auto shutdown delay

Length of time the pump continues to run

0–999 sec.

45 sec.

 

unloaded without demand from any station.

 

 

 

After this time has elapsed, the pump shuts

 

 

 

down to save power and to prevent wear on the

 

 

 

pump.

 

 

 

Adjust this setting to fit the needs of your facility

 

 

 

in trading off the savings against the costs

 

 

 

associated with waiting for a pump to start up

 

 

 

when there is a demand for material.

 

 

Alarm Options

 

 

 

Local alarm

When this option is enabled, the controller turns

disabled,

disabled

 

on the local alarm light for any alarm at this

enabled

 

 

specific pump.

 

 

 

Enable this option if and only if your facility has

 

 

 

installed a local alarm light for this pump.

 

 

Pump fault #1

The ArmorBlock for each pump has two inputs

disabled,

disabled

 

that you can wire to generate alarms for

enabled

 

 

situations of your choosing. For example, you

 

 

 

may have a sensor that turns on when material

 

 

 

reaches the top of a filter-chamber waste bin.

 

 

 

When this option is enabled, the controller

 

 

 

issues an alarm if the sensor wired to the input

 

 

 

for Pump Fault #1 turns on.

 

 

 

Enable this option if and only if your facility has

 

 

 

installed a miscellaneous alarm on the input for

 

 

 

Pump Fault #1 for this pump.

 

 

Pump fault #2

See the explanation for Pump fault #1 above.

disabled,

disabled

 

Enable this option if and only if your facility has

enabled

 

 

installed a miscellaneous alarm on the input for

 

 

 

Pump Fault #2 for this pump.

 

 

Blow Back Options

 

 

 

Blow back

When this option is enabled, the controller

disabled,

disabled

 

periodically sends compressed air backward

enabled

 

 

through the pump’s air filter to dislodge

 

 

 

accumulated dust and debris.

 

 

 

Enable this option if and only if the pump has

 

 

 

the equipment for compressed-air filter cleaning.

 

 

Every n loads

Number of conveying cycles to stations between

1–99

5

 

filter cleanings.

 

 

 

Adjust this setting based on experience. The

 

 

 

more dust and debris in your material line, the

 

 

 

smaller this number needs to be.

 

 

# pulses

Number of pulses of compressed air sent

1–99

5

 

through the pump’s filter during cleaning.

 

 

 

If blow-back is not working as desired, the

 

 

 

service department may ask you to change this

 

 

 

setting.

 

 