MODEL ICB430 INSTALLATION INSTRUCTIONS
E L E C T R I C A L R E Q U I R E M E N T S | U N PAC K I N G A N D M OV I N G | MODEL |
ICB430
A
The power supply cord has a grounding plug, which must be plugged into a mating ground-
IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
Do not use an extension cord. Electrical ground is required on this appliance.
HOME ALARM SYSTEM
If a home alarm system is to be used, refer to Home Alarm Connections on page 28. In addition to operating power, the installer may also be required to supply a home automation system lead to the unit. This is for a low- voltage,
Three 6 mm female spade connectors are located in the compressor compartment and are accessible behind the grille on Model ICB430. A minimum of 914 mm of lead wire should be provided for each contact, exiting the back wall near the electrical outlet.
Uncrate the unit, remove its wood base and discard the shipping bolts that hold the wood base to the bottom of the unit. Remove all packing materials and tape.
IMPORTANT NOTE: Do not discard the kickplate,
All
Retract the front leveling legs to allow you to move the unit more easily during installation. You will extend the leveling legs when the unit is in its final position to reduce the possibility of the unit tipping forward.
Use an appliance dolly to move the unit. Remove the drain pan from the base of the unit to avoid damage to the drain pan, and allow for proper placement of the appliance dolly.
Before moving the Wine Storage unit in to position, protect any finished flooring with appropriate materials, secure the door closed and remove the grille.
25