MODEL ICB430 INSTALLATION INSTRUCTIONS

MODEL

HOME ALARM CONNECTIONS

ICB430

Before the kickplate and grille are installed, all necessary wiring connections in the compres- sor compartment should be completed.

If a home alarm system is to be installed on the Wine Storage unit, the connections should be made using the logic supplied with the alarm specifications. See illustration 6 below for the appliance lead locations, and refer to the following for color codes:

Normally open contacts – white with red stripe wire

Normally closed contacts – white with blue stripe wire

Common – gray with white stripe wire

IMPORTANT NOTE: If you are not responsible for alarm system connection, this information should be supplied to the home security system contractor.

The alarm circuit in the unit is intended as

alow-voltage, low-current device only. It should not be used to switch line power.

Any unused terminals should be completely insulated and all wires should be secured away from conductive or moving components.

Use the 6 mm spade terminals or wire nuts provided to make the proper wiring connec- tions.

Home Alarm

Connections

Illus. 6

28