MODELS ICB424 AND ICB424FS INSTALLATION

L E V E L THE UNIT

HOME ALARM CONNECTIONS

ICB424FS

Using an adjustable wrench or pliers, turn each of the four leveling legs clockwise to raise the unit and counterclockwise to lower the unit. For the location of the leveling legs, see illustration 6 below.

For Model ICB424, the countertop bracket should be used to make a solid installation. Refer to illustration 2 on page 5. If this is not possible, wedge shims along the sides and top.

To reduce the possibility of the unit tipping forward, the front leveling legs must be in contact with the floor.

Before the kickplate is installed, all necessary wiring connections in the compressor compart- ment should be completed.

If a home alarm system is to be installed on the Wine Storage unit, the connections should be made using the logic supplied with the alarm specifications. See illustration 7 below for the appliance lead locations, and refer to the following for color codes:

Normally open contacts – white with red stripe wire

Normally closed contacts – white with blue stripe wire

Common – gray with white stripe wire

Use the 6 mm spade terminals or wire nuts provided to make the proper wiring connec- tions.

IMPORTANT NOTE: If you are not responsible for alarm system connection, this information should be supplied to the home security system contractor.

The alarm circuit in the unit is intended as

alow-voltage, low-current device only. It should not be used to switch line power.

Any unused terminals should be completely insulated and all wires should be secured away from conductive or moving components.

Leveling Legs

Illus. 6

Home Alarm

Connections

Illus. 7