MODELS ICB424 AND ICB424FS INSTALLATION
MODELS ICB424 AND ICB424FS |
| MODELS |
|
| ICB424 |
SITE PREPARATION | INSTALLATION SPECIFICATIONS | ICB424FS |
|
The
Make sure that the finished rough opening where the Wine Storage unit is to be installed is properly prepared. Refer to the Installation Specifications illustration for rough opening
TOP VIEW |
610 mm |
ROUGH |
OPENING |
DEPTH |
ROUGH OPENING
WIDTH
610mm MODEL ICB424 619 mm MODEL ICB424FS
dimensions, door swing clearance and electri- cal placement for Models ICB424 and ICB424FS.
IMPORTANT NOTE: To operate properly,
the door must open a minimum of 90 degrees. Use a minimum 76 mm filler in corner installa- tions to assure a
Allow enough clearance in front of the unit for full door swing.
MODEL ICB424 |
LOCATE ELECTRICAL |
WITHIN SHADED AREA |
114 |
mm |
394 mm |
E |
876 mm
ROUGH
OPENING
HEIGHT
870 mm
MINIMUM
HEIGHT
REQUIRED
IMPORTANT NOTE: Make sure the floor under the unit is level with the surrounding finished floor.
Do not load wine into the Wine Storage unit until the installation is complete.
64 mm |
|
|
|
|
|
| MODEL ICB424FS |
| FRONT VIEW | ||||||
|
|
|
|
| |||
|
|
|
|
|
606 mm
90˚ |
|
|
|
|
| 145˚ |
|
|
|
|
|
|
| MAXIMUM |
|
| |
|
|
| 644 mm | DOOR SWING | 645 mm | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
660 mm
DOOR CLEARANCE
1118 mm
DOOR CLEARANCE
NOTE: Door swing clearances are based on stainless steel door and handle dimensions.