1.4.5Installing the Cable Management Assembly

Use this procedure to install an optional cable management assembly (CMA).

1.Unpack the CMA parts.

2.Take the CMA to the back of the equipment rack and ensure that you have adequate room to work around the back of the server.

Note – References to “left” or “right” in this procedure assume that you are facing the back of the equipment rack.

3.Locate the CMA rail extension and insert it into the left slide-rail until the extension locks into place with an audible click. (See FIGURE 1-8.)

The CMA rail extension might be taped to the CMA assembly.

Left slide-rail

CMA rail extension

FIGURE 1-8Inserting the CMA Rail Extension Into the Back of the Left Slide-Rail

Chapter 1 System Setup 1-11